Failsafe DOL starter Electronic switching Electronic overload protection up to 4 kW / 400 V; 2.8 A to 9 A High-Feature Option: 3DI/LC module PROFIenergy
AS-i flat module, digital 4 DI/4 DQ, IP20 4 x inputs for 3-wire sensor 4 x output, 24 V DC Output supply via U_ASI Screw terminals
AS-i compact module K60 digital 4 DI/4 DQ, IP67 4 x input, maximum 200 mA 4 x output, 2 A, 24 V DC maximal 4 A for all outputs 8 x M12 socket Y-II assignment Mounting plate 3RK1901-0CA00 must be ordered separately
AS-i compact module K60 digital 4 DI/4 DQ, IP67 4 x input, maximum 200 mA 4 x output, 1 A, 24 V DC 8 x M12 socket Y-II assignment Mounting plate 3RK1901-0CA00 must be ordered separately
AS-Interface accessory Cable termination piece Sealing of open cable ends for shaped AS-i cable Degree of protection IP67
AS-Interface M12 Abzweig U_ASI und Uaux, 1 m Kabel mit M12 Kabeldose gewinkelt IP67/68/69K, maximal 4 A
Bus cable for PROFINET Pre-assembled at one end 4-core, shielded assembled with 1 x M12 D-coded Length 3.0 m
TB PEN for ET 200S Terminal block PEN for starter with connection for loads for mounting in the center
PM-D F PROFISAFE power module for fail-safe motor starter, for fail-safe contact multiplier with 6 shutdown groups for PROFIBUS or PROFINET can be plugged onto TM-PF30 S47-F1 for F-frequency converter 30 mm
Energy connection cable single-sided, open on one side Han Q4/2 angled 4 x 4 mm2 Length 5 m
Motor cable single-sided without brake without thermistor Han Q8 - open on one side angled 4 x 1.5 mm2 Length 5 m
AS-i compact module K20 digital A/B slave, 4 DI, IP67 4 x input, maximum 200 mA 4 x M8 socket
AS-i compact module K20 digital A/B slave, 4 DI/4 DQ, IP67 4 x input, maximum 200 mA 4 x output, 1 A, 24 V DC maximal 2 A for all outputs 8 x M8 sockets
SIRIUS, Central unit 3RK3 Advanced for modular Safety system 3RK3 4/8 F-DI,1F-RO,1 F-DO,24 V DC Monitoring of ASI slaves Control of 12 safe outputs on AS-Interface bus parameterizable using software Safety ES 45 mm width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) 9 extension modules connectable
SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4/8 F-DI, 24 V DC Can be parameterized via MSS ES 22.5 mm overall width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) without connection cable
SIRIUS, Extension module 3RK32 for modular Safety system 3RK3 4/8 F-RO, 24 V DC/1 A Can be parameterized via MSS ES 45 mm overall width screw terminal Up to SIL3 (IEC 61508) Up to Performance Level E (ISO 13849-1) without connection cable
SIRIUS, Interface module DP interface, for modular Safety system 3RK3 PROFIBUS DP interface 12 Kbps, RS485 45 mm overall width screw terminal Can be parameterized via MSS ES without connection cable
IO-Link module K20, digital 8 DI, IP67, 8x 1 input Sensor supply max. 400 mA 8x M8 socket standard assignment