SINAMICS V20 200-240V1AC-10/+10% 47-63Hz Rated power 3.0 kW with 150% overload for 60 sec. Integrated filter C2 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSC 184x 182x 169 (BxHxD)
SINAMICS V20 200-240V1AC-10/+10% 47-63Hz Rated power 3.0 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSC 184x 182x 169 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 0.37 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 150x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 0.37 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 150x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 0.55 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 150x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 0.55 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 150x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 0.75 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 150x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 1.1 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 166x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 1.5 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 166x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 2.2 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 166x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 2.2 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSA 90x 166x 146 (BxH
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 5.5 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSC 184x 182x 169 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 5.5 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSC 184x 182x 169 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 7.5 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSD 240x 207x 173 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 11 kW with 150% overload for 60 sec. Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSD 240x 207x 173 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 11 kW with 150% overload for 60 sec. unfiltered I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Variable: FSD 240x 207x 173 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 18.5 kW with 150% overload for 60 sec. Output low overload: 22kW with 110% overload for 60sec Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Size: FSE 244x 265x 209 (BxHxD)
SINAMICS V20 380-480V3AC-15/+10% 47-63Hz Rated power 22 kW with 150% overload for 60 sec. Output low overload: 30kW with 110% overload for 60sec Integrated filter C3 I/O interface: 4 DI, 2 DO, 2 AI, 1 AO Fieldbus: USS/MODBUS RTU with built-in BOP Degree of protection IP20/UL Op Size: FSE 244x 265x 209 (BxHxD)
SINAMICS V90, with PROFINET for Motor: 0.4 kW Degree of protection: IP20 Size B, 55x170x170 (WxHxD)
SINAMICS V90, with PROFINET for Motor: 0.75-1.0 kW Degree of protection: IP20 Size A, 80x180x200 (WxHxD)