Auxiliary switch changeover contacts type HP (14MM) accessory for 3VA1 and 3VA20 up to 3VA25
Auxiliary switch changeover contacts type HQ (7MM) accessory for 3VA1 and 3VA20 up to 3VA25
Trip alarm switch changeover contacts type HQ (7MM) accessory for 3VA1 and 3VA20 up to 3VA25
Shunt trip left 24 V AC 50/60 Hz / 24-30 V DC accessory for 3VA1 and 3VA20 up to 3VA25
Shunt trip left 208-277 V AC 50/60 Hz 220-250 V DC accessory for 3VA1 and 3VA20 up to 3VA25
Circuit breaker VL160N without Electronic Trip Unit standard breaking capacity Icu 55kA 415V AC, 3-pole In 160A, rated current without auxiliary release with box terminals for switching unit and Electronic Trip Unit
Circuit breaker VL250H high breaking capacity Icu 70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In 250A, rated current IR 200...250A, overload protection, II 1200...2500A, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUX (1 NO+1 NC)+1 AS (1 NO)
Circuit breaker VL630N standard breaking capacity Icu 55kA, 415V AC 3-pole, line protection trip unit TM, LI In 630A, rated current IR 500...630A, overload protection, II 3250...6500A, short-circuit protection without auxiliary release without auxiliary/alarm switch
ETU VL160, 3-pole, line protection thermal-magnetic, LI IR 80...100A, overload protection II 500...1000A, short-circuit protection box terminal/screw terminal connections in scope of supply of sw. unit
Accessory for VL160X, VL160, VL250, front mounted rotary operator with shaft stub without knob add. op. mech. 8UC62 required
Accessory for VL160X, VL160, VL250 door-coupling rotary op. mech. f. inst. in doors, compl. standard door op. mech. 8UC7 new design handle ti-gray, masking plate, light gray
Accessory for VL160X, VL160, VL250, VL400, auxiliary switch kit 2 HS (1NO+1NC) f. inst. N-pole/left/right
Accessory for VL630, VL800, f. inst. in doors, compl. door op. mech. 8UC7 new design handle red, masking plate yellow
Circuit breaker 3VT1 standard breaking capacity Icu 25kA, 415V AC 3-pole, line protection trip unit TM, LI In 50A rated current IR 50A overload protection II 200A, short-circuit prot. without auxiliary release without auxiliary/alarm switch
Circuit breaker 3VT1 standard breaking capacity Icu 25kA, 415V AC 4-pole, line protection trip unit TM, LIN In 50A rated current IR 40...50A overload protection II 250...500A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch
Circuit breaker 3VT1 standard breaking capacity Icu 25kA, 415V AC 3-pole, line protection trip unit TM, LI In 80A rated current IR 80A overload protection II 320A, short-circuit prot. without auxiliary release without auxiliary/alarm switch