Other control devices 

  • MAG 5000, IP67 / NEMA 4X/6, Polyamid enclosure, With display, 11-30V DC/11-24V AC 50/60 Hz

  • SIWAREX WP321 WEIGHING ELECTRONIC (1 CHANNEL) FOR STRAIN GAUGE LOAD CELLS / FULL BRIDGES (1-4 mV/V) FOR SIMATIC ET200SP, FITS to BU-TYPE A0, RS485- INTERFACE FOR CONNECTION OF SIWATOOL OR A REMOTE DISPLAY Detailed load cell diagnostics possible with digital junction box SIWAREX DB (7MH5001-0AD20 or 7MH5001-0AD01).

  • LI2Y 2X0,75ST + 2X (2X0,34ST) -CY SPECIAL CABLE, WITH BLUE SHEATH CONNECTION OF JB JUNCTION AND DISTRIBUTION BOX IN AN AREA SUBJECT TO EXPLOSION HAZARDS AND IB INTERMEDIATE BOX FOR PERMANENT ON-SITE INSTALLATION; OCCASIONAL BENDING POSSIBLE, APPROX. 10.8 MM OUTER DIAMETER, AMBIENT TEMPERATURE -40 TO +80 CEL. CABLE CUT TO LENGTH, WITHOUT CONNECTOR.

  • LI2Y 2X0,75ST + 2 (2X0,34ST) - CY, SHEATH ORANGE, SPECIAL CABLE FOR CONNECTION SIWAREX MODULE TO JB JUNCTION BOX AND DISTRIBUTION BOX OR IB INTER- MEDIATE BOX AS WELL AS BETWEEN TWO IB'S FOR PERMANENT ON-SITE INSTALLATION;OCCASIONAL BENDING POSSIBLE. 10.8 MM OUTER DIAMETER AMBIENT TEMPERATURE -40 TO +80 CEL.

  • SIWAREX FTA, FTC, MS AND M CONNECTING CABLE 9-PIN - FOR SERIAL LINKING OF SIWAREX FTA, FTC, MS AND M PC-INTERFACE (RS232C) - CABLE LENGTH 5 M

  • Service and commissioning software SIWATOOL V4 and V7 for SIWAREX weighing modules

  • SIWAREX WP231 calibratable weighing electronic (1 channel) for strain gauge load cells / full bridges (1-4 mV/V) for SIMATIC S7-1200 or stand alone, RS485 and Ethernet-Interface, onboard I/O: 4 DI / 4 DO, 1 AO (0/4...20mA), attention: for calibratable applications please follow the local laws applying in the country of verification! Detailed load cell...

  • SIWAREX DB digital junction box for enhanced diagnostics, 4 channels die-cast aluminum enclosure for connection of strain gauge load cells/full bridges (1-4mV/V) to SIWAREX weighing electronics type of protection: IP66 dimensions: 100 x 160 x 81 mm

  • Siwarex WL 230 Load Cell BB-S SA 200kg C3 - Rated Load 200kg - Accuracy class C3 - 3m Cable length, 4 Conductor - Material Stainless steel - Degree of protection IP68

  • Milltronics Motion sensing probes: heavy duty, 100 mm measuring range, for use with RMA, MFA 4p, WM300 MFA, or other control. Cable length: Standard length (per notes in model section) Model: MSP-3, 1/2" NPT conduit entry with 1.5 m (5 ft) high temperature cable, only with Remote mounted amplifier (RMA) Approval: CE,RCM,EAC,KCC

  • EchoMax XPS-10 Ultrasonic level transducer: continuous, non-contact, 10 m (32.80 ft), for liquids and solids. Mounting thread and facing: 1" NPT ((Taper), ANSI/ASME B1.20.1) Cable length: 10 m (32.81 ft) Flange, flush mount: No flange Approvals: ATEX II 2GD,FM Class I Div 2/SAA Class 1 Zone 1 .

  • EchoMax XPS-10 Ultrasonic level transducer: continuous, non-contact, 10 m (32.80 ft), for liquids and solids. Mounting thread and facing: 1" NPT ((Taper), ANSI/ASME B1.20.1), FOAM facing Cable length: 30 m (98.43 ft) Flange, flush mount: No flange Approvals: CSA Class 1 Div. 1 .

  • EchoMax XPS-15 Ultrasonic level transducer: continuous, non-contact, 15 m (49.21 ft), for liquids and solids. Mounting thread and facing: 1" NPT ((Taper), ANSI/ASME B1.20.1) Cable length: 10 m (32.81 ft) Flange: No Mounting flange Approvals: CSA Class 1 Div 1 (available only with Mounting Options 0, 1 and 2) Manual: Multi-Language,Quick Start

  • EchoMax XPS-30 Ultrasonic level transducer: continuous, non-contact, 30 m (98.42 ft) for liquids and solids. Mounting thread and facing: 1 1/2" universal thread Cable length: 5 m (16.40 ft) Flange: Without mounting flange Approvals: ATEX II 2G 1D, FM Class 1 Div 2, SAA Instruction Manual: Multi-Language Quick Start

  • EchoMax XPS-30 Ultrasonic level transducer: continuous, non-contact, 30 m (98.42 ft) for liquids and solids. Mounting thread and facing: 1 1/2" universal thread Cable length: 30 m (98.43 ft) Flange: Without mounting flange Approvals: ATEX II 2G 1D, FM Class 1 Div 2, SAA Instruction Manual: Multi-Language Quick Start

  • Pointek ULS200 Ultrasonic point level switch: non-contact, 5 m (16.4 ft) range, for bulk solids, liquids, and slurries. Power supply: 24 VDC, Relay output Approvals: CE, C-TICK, CSA US/C, FM Transducer/Process connection: PVDF copolymer, R 2" ((BSPT), EN 10226) . Enclosure/cable inlet: Polycarbonate housing, Cable inlet PG 13.5

  • UNIVERSAL BOX BRACKET, FMS-200

  • LOCKNUT,2" BSPT, PLASTIC

  • LOCKNUT, 2" NPT, Nylon

  • MultiRanger 100/200 Ultrasonic level controller: continuous, non-contact, 15 m (50 ft) range. Monitors level, volume, and open channel flow in liquids, slurries, and solids. Versions: MultiRanger 200, level, volume, flow and differential measurements Mounting, enclosure design: Wall mount, standard enclosure Input voltage: 100 to 230 VAC Number of...