Power contactor, AC-3 265 A, 132 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S10 Busbar connections Drive: conventional screw terminal
Power contactor, AC-3 265 A, 132 kW / 400 V AC (50-60 Hz) / DC operation 200-277 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S10 Busbar connections Drive: electronic with PLC interface 24 V DC screw terminal
Power contactor, AC-3 300 A, 160 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S10 Busbar connections Drive: conventional screw terminal
Power contactor, AC-3 400 A, 200 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S12 Busbar connections Drive: conventional screw terminal
Vacuum contactor, AC-3 500 A, 250 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S12 Busbar connections Drive: conventional
Contactor, AC-1, 60 A, 24 V AC, 50 Hz, 4-pole, Size S2, Screw terminal, Successor is SIRIUS 3RT2 Preferred successor type is 3RT2336-1AB00
Power contactor, AC-1 275 A, 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 Busbar connections Drive: conventional
Contactor, AC-1, 400 A 230 (50...60 Hz) / DC operation 220 ... 240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S10 Busbar connections Drive: conventional
Power contactor, AC-1 690 A / 690 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S12 Busbar connections Drive: conventional
Replacement contact pieces for contactor Size S3, 3-pole, AC-3, 37 kW, 3 NO, main contacts, consists of 3 movable and 6 fixed contacts with mounting parts, Successor is SIRIUS 3RT2
Replacement contact pieces for Size S6, for contactor 3RT1054, 55 kW / AC-3, consists of 3 movable and 6 fixed contacts with mounting parts
Box terminal block for contactor size S6, 3RT105 for overload relay 3RB105 max. connection approx. 70 mm2
Withdrawable coil for size S6 for contactors 3RT105 / 3RT145 AC/DC operation 200 ... 277 V UC, Drive: electronic with PLC interface 24 V DC Spring-type terminal
Replacement contact pieces for Size S6, for contactor 3RT1055, 75 kW / AC-3, consists of 3 movable and 6 fixed contacts with mounting parts
Terminal cover for busbar connections for contactor size S6, 3RT1.5 for overload relay 3RB2.5 for soft starter 3RW405 3RW442., 3RW443.
Terminal cover for box terminal block for contactor size S6, 3RT1.5 for overload relay 3RB105 for soft starter 3RW405 3RW442., 3RW443.
Box terminal block for contactor size S6, 3RT1.5 for overload relay 3RB105 max. connection approx. 120 mm2
Replacement contact pieces for Size S6, for contactor 3RT1056, 90 kW / AC-3, consists of 3 movable and 6 fixed contacts with mounting parts
Replacement contact pieces for Size S10, for contactor 3RT1064, 110 kW / AC-3, consists of 3 movable and 6 fixed contacts with mounting parts
Replacement contact pieces for Size S10, for contactor 3RT1065, 132kW / AC-3, consists of 3 movable and 6 fixed contacts with mounting parts