Connecting cable Length 1.0 m, round, for connection of basic unit, current measuring module, current/voltage measuring module, operator panel or extension modules via the system interface
USB PC cable for connection to the USB interface of a PC, for communication with SIMOCODE pro or SIRIUS 3RW44 soft starter or modular safety system 3RK3 via the system interface
Analog monitoring relay Fill level monitoring Resistance monitoring from 2 to 200 kohm 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC 2-step or 1-step control Tripping delay 0.5 to 10 s 1 change-over contact screw terminal Successor product for 3UG3501
Analog monitoring relay Phase failure and sequence 3 x 160...690 V 50...60 Hz AC 1 change-over contact screw terminal
Analog monitoring relay Phase failure and sequence Adjustable undervoltage Asymmetry 20% fixed 3 x 160 to 690 V 50 to 60 Hz AC Hysteresis 5% fixed Delay time 0-20 s 2 change-over contacts screw terminal Successor product for 3UG3013-1B...
Digital monitoring relay Asymmetry 0-20% Phase sequence can be activated Phase failure 3 x 160 to 690 V 50 to 60 Hz AC Undervoltage 160-690 V Hysteresis 1-20 V ON and OFF delay 0-20 s 2 change-over contacts screw terminal Successor product for 3UG3012-1A...
Digital monitoring relay Asymmetry 0-20% Phase sequence can be activated Phase failure 3 x 160 to 690 V 50 to 60 Hz AC Undervoltage 160-690 V Hysteresis 1-20 V ON and OFF delay 0-20 s 2 change-over contacts spring-type connection system
Digital monitoring relay 3-phase supply voltage Phase sequence can be activated Phase failure 3 x 160 to 690 V 50 to 60 Hz AC Undervoltage and overvoltage 160-690 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax screw terminal Successor product for 3UG3041-1BP50
Digital monitoring relay for 3-phase voltage with N-conductor Phase sequence can be activated Phase failure 3 x 90 to 400 V 50 to 60 Hz AC Undervoltage and overvoltage 90-400 V Hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax Spring-type terminal
Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3522-1AL20, 3UG3522-1AG20 and 3UG3522-1AC48-0AA1
Digital monitoring relay Voltage monitoring, 22.5 mm from 10 to 600 V AC/DC 0vershoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC Noise pulses delay 0.1 to 20 s Hysteresis 0.1 to 300 V 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3532-1AL20, 3UG3532-1AG20
Digital monitoring relay Speed monitoring from 0.1 to 2200 rpm Overshoot and undershoot 24 to 240 V AC/DC 50 to 60 Hz DC and AC ON delay 1 to 900 s Tripping delay 0.1 to 99.9 s Hysteresis 0.1 to 99 rpm 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3051
Digital monitoring relay cos phi and current monitoring for IO-Link 90...690 V AC, 0.2...10 A 0vershoot and undershoot ON-delay time Tripping delay time Hysteresis 0.1 to 3.0 A 2 change-over contacts, screw terminal
Circuit breaker 3VA1 IEC Frame 100 Switching capacity class N Icu 25 kA 415 V 3-pole, system protection TM210, FTFM, In 100 A Overload protection Ir 100 A non-adjustable short-circuit protection Ii 10 x In Lug terminal
Circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu 25kA 415V 3-pole, line protection TM210, FTFM, In 63A overload protection Ir 63A fixed short-circuit protection Ii 10 x In nut keeper kit
Circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu 25kA 415V 3-pole, line protection TM210, FTFM, In 80A overload protection Ir 80A fixed short-circuit protection Ii 10 x In clamp connection
Circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu 55kA 415V 3-pole, line protection TM240, ATAM, In 100A overload protection Ir 70A...100A short-circuit protection Ii 5...10 x In nut keeper kit
Circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu 55kA 415V 3-pole, line protection TM240, ATAM, In 100A overload protection Ir 70A...100A short-circuit protection Ii 5...10 x In clamp connection
Circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu 70kA 415V 3-pole, line protection TM240, ATAM, In 100A overload protection Ir 70A...100A short-circuit protection Ii 5...10 x In clamp connection