Other Sinamics 

  • SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 45KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 55KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

  • SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT...

  • SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 55KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 75KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

  • SINAMICS G120 POWER MODULE PM250 WITH BUILT IN CL. A FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 934 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT...

  • SINAMICS G120 POWER MODULE PM250 WITHOUT FILTER POSSIBILITY OF REGENERATION 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 75KW FOR 200% 3S,150% 57S,100% 240S AMBIENT TEMP 0 TO +50 DEG C OUTPUT LIGHT OVERLOAD: 90KW FOR 150% 3S,110% 57S,100% 240S AMBIENT TEMP 0 TO +40 DEG C 634 X 350 X 316 (HXWXD), FSF PROTECTION IP20 WITHOUT CONTROL UNIT AND BOP

  • SINAMICS G120 CU240E-2 F Control Unit E-type Safety Integrated STO F-type SS1, SLS, SSM, SDI RS 485 interface 6 DI, 3 DQ, 2 AI, 2 AQ, max. 3 F-DI PTC/KTY interface USB and SD/MMC interface Degree of protection IP20 Ambient temperature 0 to +50 C without Power Module

  • SINAMICS G120 CU240E-2 DP-F Control Unit E-type Safety Integrated STO F-type SS1, SLS, SSM, SDI PROFIBUS DP 6 DI, 3 DQ, 2 AI, 2 AQ, max. 3 F-DI PTC/KTY interface USB and SD/MMC interface Degree of protection IP20 Ambient temperature 0 to +50 C without Power Module

  • SINAMICS G120 Control Unit CU250S-2 integrated RS485/USS/ MODBUS RTU supports vector control Basic positioner EPOS via License extended functions 4 configurable DI/DO 6 DI (3 F-DI), 5 DI 3 DO (1 F-DO) 2 AI, 2 AO Safety Integrated STO, SBC, SS1 Additional safety functions via EXTENDED SAFETY license Encoder interface: D-CLiQ+HTL/TTL/SSI Resolver/HTL via...

  • SINAMICS G120 Control Unit CU250S-2 CAN Integrated CANopen supports vector control Basic positioner EPOS via License extended functions 4 configurable DI/DO 6 DI (3 F-DI), 5 DI 3 DO (1 F-DO) 2 AI, 2 AO Safety Integrated STO, SBC, SS1 Additional safety functions via EXTENDED SAFETY license Encoder interface: D-CLiQ+HTL/TTL/SSI Resolver/HTL via terminal...

  • SINAMICS G110/G120 PC-inverter connecting kit 3 m RS232 standard cable and a 9-pin D-sub adapter for connection to G110 and G120 Control Units CU240E CU240S

  • SINAMICS G120 CM240NE chemical industry module for operation with CU240S DP-F CU250S-2 DP ATEX-certified PTC thermistor evaluation, NAMUR terminal block for operation with CU250S-2 DP the add-on kit for CM240NE (6SL3260-4TA00-1AA6) required (mounting rail mounting)

  • SINAMICS V20 BOP interface Variable: 49x56x23 (WxHxD)

  • SINAMICS V20 BOP Variable: 76x85x30 (WxHxD)

  • SINAMICS V20 Parameter loader Variable: 90x57x28 (WxHxD)

  • SINAMICS V20 I/O EXTENSION MODULE I/O INTERFACE: 2 DI, 2 RELAY

  • DEMOCASE SINAMICS G150 eine Box, Motor integriert

  • DEMO CASE SINAMICS G150 Two boxes Separate motor in second box

  • DEMOCASE SINAMICS S150 Two boxes Separate motor in second box

  • Backplane bus module 155 mm for ET 200 PRO frequency converter

  • SINAMICS G120 Supplementary kit CM240NE chemical industry module for mounting on DIN rail consisting of adapter according to DIN 50022 (35x 15 mm) and Cable harness